deutsch deutsch

 

ASME - UD - TÜV Nord

 

Product range


Composite bursting discs – Typ C

Directly between flanges – bi-directional

Construction:
Flat, slotted, non fragmenting öffnend

Operating conditions:
Gas, Vapour and Liquids

Operating temperature:
-80°C to +150 °C because of PTFE sealing

Features
  • operating ratio 80% at 20°C
  • lowest burst pressure can be realized
  • low resistance against alternating loads
  • very good tightness
  • full vacuum resistant
  • tolerant of different fastening torques
  • surveillance of burst possible
  • installation directly between flanges possible
 

 

Performance tolerance:
(including material, production and testing tolerances)

  Burst pressure in bar
DN < 0,05 0,05 - 0,1 0,1 - 0,5 0,5 - 1 1 - 20 > 20
20     ± 15 % ± 10 % ± 10 % ± 5 %
25     ± 15 % ± 10 % ± 10 % ± 5 %
40     ± 15 % ± 10 % ± 10 % ± 5 %
50   ± 20 % ± 15 % ± 10 % ± 10 % ± 5 %
65   ± 20 % ± 15 % ± 10 % ± 10 % ± 5 %
80   ± 20 % ± 15 % ± 10 % ± 10 % ± 5 %
100 ± 10 mbar ± 20 % ± 15 % ± 10 % ± 10 % ± 5 %
150 ± 10 mbar ± 20 % ± 15 % ± 10 % ± 10 %  
200 ± 10 mbar ± 20 % ± 15 % ± 10 % ± 10 %  
250 ± 10 mbar ± 20 % ± 15 % ± 10 % ± 10 %  
300 ± 10 mbar ± 20 % ± 15 % ± 10 %    
400 ± 10 mbar ± 20 % ± 15 % ± 10 %    
500 ± 10 mbar ± 20 % ± 15 % ± 10 %    
600 ± 10 mbar ± 20 % ± 15 % ± 10 %    
700 ± 10 mbar ± 20 % ± 15 % ± 10 %    
800 ± 10 mbar ± 20 % ± 15 % ± 10 %    

 

 

 

Questionnaire for dimensioning
Questionnaire_for_dimensioning.pdf

(Please do not hesitate to contact us in case of any question)

phone: +49 23 55/ 92 710

email: info@schlesinger-gmbh.de

 

 

©2009 Berstscheiben Schlesinger GmbH