Installation of bursting discs


The right method of installation is determinative for optimal usage of bursting discs. Bursting discs with nominal widths of over 25 mm, such as are used in the chemical industry for making safe reactors and transport tanks, are usually installed between standard flanges. A special holder is often necessary for this purpose. Schlesinger bursting discs can in most cases be installed directly between flanges. This not only saves costs, but also increases flexibility for the customer. However, there are designs of bursting discs which require a special holder into which the bursting discs are inserted before the complete bursting device is clamped between flanges:
  • when a signal transmitter is required
  • when reverse bursting discs are used (in most cases)
  • for rupturing disks with very high burst pressures (pre-cambered bursting disks)
Care must be taken when installing a bursting disc before a safety valve that the enclosed pressurised area between the bursting disc and the safety valve must be monitored and, if appropriate, ventilated with an overflow valve. Bursting discs before safety valves must open fragmentation-free, for which reason it is absolutely necessary to inform us of the installation situation. For small bursting discs a very wide variety of installation options arise:
  • in standardised fittings such as locking ring-manometer fittings or VCR fittings
  • in special fittings (high pressure fittings or special designs) as bursting plugs simply installed in a threaded screw
  • between the different clamp fittings
  • all-metal designs can be welded on

In all events, care must be taken that the circumstances in our test fitting are identical to the installation situation at the customer, since otherwise the assured properties are not guaranteed.
All types of installation can be inspected with a helium sealing test.
It is important that the identification must not be concealed by the installation.

Installation situations

High-purity gas fitting
for high vacuum and high purity gases:bursting discs in VCR-fitting
Installation between flanges
Standard installation situation in the chemical industry and in construction of containers: bursting discs clamped directly - without holder - between flangest
Tri-clamp fitting
for bursting discs

 

Back to question overview

 

Further information: Mounting options